Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 514
Filtrar
1.
Int J Mol Sci ; 25(7)2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38612497

RESUMO

Scar tissue formation presents a significant barrier to peripheral nerve recovery in clinical practice. While different experimental methods have been described, there is no clinically available gold standard for its prevention. This study aims to determine the potential of fibrin glue (FG) to limit scarring around peripheral nerves. Thirty rats were divided into three groups: glutaraldehyde-induced sciatic nerve injury treated with FG (GA + FG), sciatic nerve injury with no treatment (GA), and no sciatic nerve injury (Sham). Neural regeneration was assessed with weekly measurements of the visual static sciatic index as a parameter for sciatic nerve function across a 12-week period. After 12 weeks, qualitative and quantitative histological analysis of scar tissue formation was performed. Furthermore, histomorphometric analysis and wet muscle weight analysis were performed after the postoperative observation period. The GA + FG group showed a faster functional recovery (6 versus 9 weeks) compared to the GA group. The FG-treated group showed significantly lower perineural scar tissue formation and significantly higher fiber density, myelin thickness, axon thickness, and myelinated fiber thickness than the GA group. A significantly higher wet muscle weight ratio of the tibialis anterior muscle was found in the GA + FG group compared to the GA group. Our results suggest that applying FG to injured nerves is a promising scar tissue prevention strategy associated with improved regeneration both at the microscopic and at the functional level. Our results can serve as a platform for innovation in the field of perineural regeneration with immense clinical potential.


Assuntos
Cicatriz , Traumatismos dos Nervos Periféricos , Animais , Ratos , Cicatriz/prevenção & controle , Adesivo Tecidual de Fibrina/farmacologia , Traumatismos dos Nervos Periféricos/prevenção & controle , Nervo Isquiático , Músculos
2.
J Cardiothorac Surg ; 19(1): 149, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38515189

RESUMO

OBJECTIVE: Our previous study revealed that the viscosity of fibrinogen could influence the effectiveness of ventilation and anchoring (V/A) methods for controlling air leakages. Here, we examined the association between the viscosity of fibrinogen and effectiveness using an ex vivo pig model. METHODS: The fibrin glue used in this study was BOLHEAL® (KM Biologics Co., Ltd., Kumamoto, Japan). We prepared three types of fibrinogen with different viscosities (higher and lower than normal), including one without additives. Using an ex vivo pig model, a pleural defect was made, and the defect was repaired using three different viscosities of fibrinogen through the V/A method. We measured the rupture pressure at the repair site (N = 10) and histologically evaluated the depth of fibrin infiltration into the lung parenchyma at the repair sites. RESULTS: The median rupture pressure was 51.5 (40-73) cmH2O in Group 1 (lower viscosity), 47.0 (47-88) cmH2O in Group 2 (no change in viscosity), and 35.5 (25-61) cmH2O in Group 3 (higher viscosity). There was no statistically significant difference between Groups 1 and 2 (p = 0.819), but the rupture pressure was significantly higher in Group 2 than in Group 3 (p = 0.0136). Histological evaluation revealed deep infiltration of fibrin into the lung parenchyma in Groups 1 and 2, but no such infiltration was observed in the higher-viscosity group. CONCLUSIONS: The results of this experiment suggested that the V/A method using fibrin glue containing low-viscosity fibrinogen was more effective in controlling air leakage due to pleural defects.


Assuntos
Adesivo Tecidual de Fibrina , Hemostáticos , Animais , Suínos , Adesivo Tecidual de Fibrina/farmacologia , Adesivo Tecidual de Fibrina/uso terapêutico , Viscosidade , Fibrinogênio/uso terapêutico , Pulmão/patologia
3.
Eur J Pharm Sci ; 192: 106610, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37852309

RESUMO

INTRODUCTION: Arterial restenosis caused by intimal hyperplasia (IH) is a serious complication after vascular interventions. In the rat carotid balloon injury model, we injected phosphate buffer saline (PBS), rapamycin-phosphate buffer saline suspension (RPM-PBS), blank fibrin glue (FG) and rapamycin-fibrin glue (RPM-FG) around the injured carotid artery under ultrasound guidance and observed the inhibitory effect on IH. METHODS: The properties of RPM-FG in vitro were verified by scanning electron microscopy (SEM) and determination of the drug release rate. FG metabolism in vivo was observed by fluorescence imaging. The rat carotid balloon injury models were randomly classified into 4 groups: PBS group (control group), RPM-PBS group, FG group, and RPM-FG group. Periadventitial administration was performed by ultrasound-guided percutaneous puncture on the first day after angioplasty. Carotid artery specimens were analyzed by immunostaining, Evans blue staining and hematoxylin-eosin staining. RESULTS: The RPM particles showed clustered distributions in the FG block. The glue was maintained for a longer time in vivo (> 14 days) than in vitro (approximately 7 days). Two-component liquid FG administered by ultrasound-guided injection completely encapsulated the injured artery before coagulation. The RPM-FG inhibited IH after carotid angioplasty vs. control and other groups. The proliferation of vascular smooth muscle cells (VSMCs) was significantly inhibited during neointima formation, whereas endothelial cell (EC) repair was not affected. CONCLUSION: Periadventitial delivery of RPM-FG contributed to inhibiting IH in the rat carotid artery injury model without compromising re-endothelialization. Additionally, FG provided a promising platform for the future development of a safe, effective, and minimally invasive perivascular drug delivery method to treat vascular disease.


Assuntos
Lesões das Artérias Carótidas , Neointima , Ratos , Animais , Hiperplasia/tratamento farmacológico , Hiperplasia/complicações , Neointima/tratamento farmacológico , Neointima/complicações , Adesivo Tecidual de Fibrina/farmacologia , Adesivo Tecidual de Fibrina/uso terapêutico , Proliferação de Células , Ratos Sprague-Dawley , Lesões das Artérias Carótidas/tratamento farmacológico , Lesões das Artérias Carótidas/metabolismo , Ultrassonografia de Intervenção , Fosfatos
4.
Indian J Ophthalmol ; 72(2): 223-227, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38099382

RESUMO

PURPOSE: To evaluate the clinical outcomes with fibrin glue in comparison with vicryl sutures for limbal conjunctival wound closure in strabismus surgery. METHODS: In this prospective interventional study, patients undergoing horizontal muscle strabismus surgery were randomized into two groups: the vicryl suture group and the fibrin glue group. The limbal conjunctival incisions were closed with 8-0 vicryl in the suture group and with fibrin glue in the other group. The outcomes measured were post-operative conjunctival inflammation and wound apposition, patient comfort with the help of a questionnaire, and conjunctival thickness using anterior segment optical coherence tomography (AS-OCT) for both groups at 6 weeks. RESULTS: The study included 64 eyes of 64 patients (32 eyes in each group). The fibrin glue group performed better than the vicryl suture group for most of the symptoms like redness, irritation, watering, and foreign body sensation till 2 weeks post-operatively ( P < 0.001), after which both the groups performed similarly. As for clinical signs, no significant difference was noted between the two groups, except for conjunctival hyperemia, which was significantly lesser in the fibrin glue group at 2 weeks post-operatively ( P < 0.001). The conjunctival thickness measured at 6 weeks using AS-OCT revealed that the thickness increased significantly in the suture group compared to that in the glue group ( P < 0.001 medial site, P = 0.004 lateral site). CONCLUSION: Because of greater patient comfort and reduced inflammation associated with fibrin glue, it may be considered as a procedure of choice for conjunctival wound closure in strabismus surgery in the absence of the cost constraints.


Assuntos
Conjuntivite , Pterígio , Estrabismo , Adesivos Teciduais , Humanos , Adesivo Tecidual de Fibrina/farmacologia , Adesivo Tecidual de Fibrina/uso terapêutico , Adesivos Teciduais/uso terapêutico , Poliglactina 910 , Estudos Prospectivos , Túnica Conjuntiva/cirurgia , Técnicas de Sutura , Estrabismo/cirurgia , Inflamação , Suturas , Pterígio/cirurgia
5.
Medicina (Kaunas) ; 59(12)2023 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-38138181

RESUMO

Background and Objectives: The efficacy of tranexamic acid (TXA) in reducing perioperative blood loss during total knee arthroplasty (TKA) is well established. However, the potential synergistic blood-conservation effect of topical fibrin sealant (Tisseel@) remains unclear. This study aims to assess the effectiveness of the combination of Tisseel and TXA during TKA. Materials and Methods: A single-blinded, prospective, randomized controlled trial was conducted with 100 patients (100 knees) undergoing primary TKA. Participants were randomly assigned to either the TXA group (n = 50), receiving intravenous (IV) TXA, or the Tisseel@ + TXA group (n = 50), receiving intra-articular Tisseel@ combined with IV TXA. The primary outcomes included blood transfusion rate, decrease in Hb level, calculated blood loss, and estimated total postoperative blood loss. Secondary outcomes involved assessing clinical differences between the groups. Results: The transfusion rate was zero in both groups. The average estimated blood loss in the Tisseel@ + TXA group was 0.463 ± 0.2422 L, which was similar to that of the TXA group at 0.455 ± 0.2522 L. The total calculated blood loss in the Tisseel@ + TXA group was 0.259 ± 0.1 L, compared with the TXA group's 0.268 ± 0.108 L. The mean hemoglobin reduction in the first 24 h postoperatively was 1.57 ± 0.83 g/dL for the Tisseel@ + TXA group and 1.46 ± 0.82 g/dL for the TXA-only group. The reduction in blood loss in the topical Tisseel@ + TXA group was not significantly different from that achieved in the TXA-only group. The clinical results of TKA up to the 6-week follow-up were comparable between the groups. Conclusions: The combination of the topical fibrin sealant Tisseel@ and perioperative IV TXA administration, following the described protocol, demonstrated no significant synergistic blood-conservation effect in patients undergoing TKR.


Assuntos
Antifibrinolíticos , Artroplastia do Joelho , Ácido Tranexâmico , Humanos , Ácido Tranexâmico/farmacologia , Ácido Tranexâmico/uso terapêutico , Adesivo Tecidual de Fibrina/farmacologia , Adesivo Tecidual de Fibrina/uso terapêutico , Antifibrinolíticos/farmacologia , Antifibrinolíticos/uso terapêutico , Artroplastia do Joelho/efeitos adversos , Estudos Prospectivos , Perda Sanguínea Cirúrgica/prevenção & controle
6.
Sci Rep ; 13(1): 20001, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37968507

RESUMO

To construct an injectable fibrin glue system loaded with kaempferol (FG@F) to improve the bioavailability of kaempferol and observe its efficacy in the treatment of intervertebral disc degeneration (IVDD). Kaempferol-loaded fibrin glue was first synthesized in advance. Subsequently, the materials were characterized by various experimental methods. Then, nucleus pulposus cells (NPCs) were stimulated with lipopolysaccharide (LPS) to establish a degenerative cell model, and the corresponding intervention treatment was conducted to observe the effect in vitro. Finally, the tail disc of rats was punctured to establish a model of IVDD, and the therapeutic effect of the material in vivo was observed after intervertebral disc injection. The FG@F system has good injectability, sustained release and biocompatibility. This treatment reduced the inflammatory response associated with IVDD and regulated matrix synthesis and degradation. Animal experimental results showed that the FG@F system can effectively improve needle puncture-induced IVDD in rats. The FG@F system has better efficacy than kaempferol or FG alone due to its slow release and mechanical properties. The drug delivery and biotherapy platform based on this functional system might also serve as an alternative therapy for IVDD.


Assuntos
Degeneração do Disco Intervertebral , Disco Intervertebral , Núcleo Pulposo , Ratos , Animais , Degeneração do Disco Intervertebral/tratamento farmacológico , Degeneração do Disco Intervertebral/metabolismo , Adesivo Tecidual de Fibrina/farmacologia , Quempferóis/farmacologia , Quempferóis/metabolismo , Disco Intervertebral/metabolismo , Núcleo Pulposo/metabolismo , Inflamação/tratamento farmacológico , Inflamação/metabolismo
7.
Sci Rep ; 13(1): 13140, 2023 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-37573402

RESUMO

Demineralized dentin matrix (DDM) is an osteoconductive and osteoinductive material that has been successfully used in sinus floor augmentation and alveolar ridge augmentation in clinical applications. It releases bone morphogenetic proteins (BMPs) and other growth factors, making DDM a suitable grafting material. However, the granular particle of DDM makes it difficult to anchor into the bone defect area. The aim of this study was to investigate the biological effects and osteoinductivity of the combination of DDM and Fibrin Glue (FG) at an optimal ratio on bone healing from a critical bone defect in an animal model. The mouse osteoblastic cell line (MC3T3-E1) was co-cultured with various ratios of DDM and FG to examine their effects on osteoblast proliferation and differentiation, as indicated by alkaline phosphatase (ALP) activity, osteocalcin (OC) production and mineralized nodules formation. The optimal ratio was then chosen for further study with a rabbit calvarial defective model, in which they were implanted with DDM or DDM-FG1 (1 g: 0.1 ml) and DDM-FG2 (1 g: 0.5 ml) compounds, or left blank for 2, 4, 8 and 12 weeks to investigate soft tissue and new bone regeneration. Micro-CT and histology analysis were used to evaluate the total grafting properties according to the different healing periods. The result from in vitro studies demonstrated that the ratio of 1:0.1 induced more ALP activity and mineralized nodules, while the ratio of 1: 0.5 (DDM-FG combined) induced more osteocalcin (OC) at specific time points. In the animal model, the 3D new bone volume in all DDM-FG treatment groups was significantly greater than that in the blank group at 2, 4, 8 and 12 weeks. Furthermore, the new bone volume was greater in DDM-FG2 when compared to the other groups during the early weeks of the healing period. In histological analysis, clusters of osteoblasts were formed adjacent to the DDM particles, and newly formed bone was observed in all groups, suggesting an osteoinductive property of DDM. Moreover, the greater new collagen synthesis observed at 4 weeks suggested that early bone healing was induced in the DDM-FG2 group. This study demonstrated that at an optimal ratio, the DDM-FG compound enhances osteogenic activities and bone regeneration.


Assuntos
Osteogênese , Levantamento do Assoalho do Seio Maxilar , Camundongos , Animais , Coelhos , Adesivo Tecidual de Fibrina/farmacologia , Osteocalcina , Dentina , Regeneração Óssea , Diferenciação Celular
8.
J Control Release ; 361: 621-635, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37572963

RESUMO

The semi-permeable round window membrane (RWM) is the gateway to the cochlea. Although the RWM is considered a minimally invasive and clinically accepted route for localised drug delivery to the cochlea, overcoming this barrier is challenging, hindering development of effective therapies for hearing loss. Neurotrophin 3 (NT3) is an emerging treatment option for hearing loss, but its therapeutic effect relies on sustained delivery across the RWM into the cochlea. Silica supraparticles (SPs) are drug delivery carriers capable of providing long-term NT3 delivery, when injected directly into the guinea pig cochlea. However, for clinical translation, a RWM delivery approach is desirable. Here, we aimed to test approaches to improve the longevity and biodistribution of NT3 inside the cochlea after RWM implantation of SPs in guinea pigs and cats. Three approaches were tested (i) coating the SPs to slow drug release (ii) improving the retention of SPs on the RWM using a clinically approved gel formulation and (iii) permeabilising the RWM with hyaluronic acid. A radioactive tracer (iodine 125: 125I) tagged to NT3 (125I NT3) was loaded into the SPs to characterise drug pharmacokinetics in vitro and in vivo. The neurotrophin-loaded SPs were coated using a chitosan and alginate layer-by-layer coating strategy, named as '(Chi/Alg)SPs', to promote long term drug release. The guinea pigs were implanted with 5× 125I NT3 loaded (Chi/Alg) SPs on the RWM, while cats were implanted with 30× (Chi/Alg) SPs. A cohort of animals were also implanted with SPs (controls). We found that the NT3 loaded (Chi/Alg)SPs exhibited a more linear release profile compared to NT3 loaded SPs alone. The 125I NT3 loaded (Chi/Alg)SPs in fibrin sealant had efficient drug loading (~5 µg of NT3 loaded per SP that weights ~50 µg) and elution capacities (~49% over one month) in vitro. Compared to the SPs in fibrin sealant, the (Chi/Alg)SPs in fibrin sealant had a significantly slower 125I NT3 drug release profile over the first 7 days in vitro (~12% for (Chi/Alg) SPs in fibrin sealant vs ~43% for SPs in fibrin sealant). One-month post-implantation of (Chi/Alg) SPs, gamma count measurements revealed an average of 0.3 µg NT3 remained in the guinea pig cochlea, while for the cat, 1.3 µg remained. Histological analysis of cochlear tissue revealed presence of a 125I NT3 signal localised in the basilar membrane of the lower basal turn in some cochleae after 4 weeks in guinea pigs and 8 weeks in cats. Comparatively, and in contrast to the in vitro release data, implantation of the SPs presented better NT3 retention and distribution inside the cochlea in both the guinea pigs and cats. No significant difference in drug entry was observed upon acute treatment of the RWM with hyaluronic acid. Collectively, our findings indicate that SPs and (Chi/Alg)SPs can facilitate drug transfer across the RWM, with detectable levels inside the cat cochlea even after 8 weeks with the intracochlear approach. This is the first study to examine neurotrophin pharmacokinetics in the cochlea for such an extended period of times in these two animal species. Whilst promising, we note that outcomes between animals were variable, and opposing results were found between in vitro and in vivo release studies. These findings have important clinical ramifications, emphasising the need to understand the physical properties and mechanics of this complex barrier in parallel with the development of therapies for hearing loss.


Assuntos
Surdez , Perda Auditiva , Animais , Cobaias , Gatos , Adesivo Tecidual de Fibrina/farmacologia , Ácido Hialurônico , Distribuição Tecidual , Cóclea , Janela da Cóclea/patologia , Janela da Cóclea/cirurgia , Perda Auditiva/terapia , Fatores de Crescimento Neural
9.
J Biomater Appl ; 37(10): 1858-1873, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37082911

RESUMO

BACKGROUND: Commercial fibrin glue is increasingly finding its way into clinical practice in surgeries to seal anastomosis, and initiate hemostasis or tissue repair. Human biological glue is also being discussed as a possible cell carrier. To date, there are only a few studies addressing the effects of fibrin glue on the cell-molecular level. This study examines the effects of fibrin glue on angiogenesis and lymphangiogenesis, as well as adipose-derived stem cells (ASCs) with a focus on gene and protein expression in scaffolds regularly used for tissue engineering approaches. METHODS: Collagen-based dermal regeneration matrices (DRM) were seeded with human umbilical vein endothelial cells (HUVEC), human dermal lymphatic endothelial cells (LECs), or adipose-derived stem cells (ASC) and fixed with or without fibrin glue according to the experimental group. Cultures were maintained for 1 and 7 days. Finally, angiogenic and lymphangiogenic gene and protein expression were measured with special regard to subtypes of vascular endothelial growth factor (VEGF) and corresponding receptors using Multiplex-qPCR and ELISA assays. In addition, the hypoxia-induced factor 1-alpha (HIF1a) mediated intracellular signaling pathways were included in assessments to analyze a hypoxic encapsulating effect of fibrin polymers. RESULTS: All cell types reacted to fibrin glue application with an alteration of gene and protein expression. In particular, vascular endothelial growth factor A (VEGFA), vascular endothelial growth factor B (VEGFB), vascular endothelial growth factor C (VEGFC), vascular endothelial growth receptor 1 (VEGFR1/FLT1), vascular endothelial growth receptor 2 (VEGFR2/KDR), vascular endothelial growth receptor 3 (VEGFR3/FLT4) and Prospero Homeobox 1 (PROX1) were depressed significantly depending on fibrin glue. Especially short-term fibrin effect led to a continuous downregulation of respective gene and protein expression in HUVECs, LECs, and ASCs. CONCLUSION: Our findings demonstrate the impact of fibrin glue application in dermal regeneration with special regard to angiogenesis and lymphangiogenesis. In particular, a short fibrin treatment of 24 hours led to a decrease in gene and protein levels of LECS, HUVECs, and ASCs. In contrast, the long-term application showed less effect on gene and protein expressions. Therefore, this work demonstrated the negative effects of fibrin-treated cells in tissue engineering approaches and could affect wound healing during dermal regeneration.


Assuntos
Linfangiogênese , Fator A de Crescimento do Endotélio Vascular , Humanos , Fator A de Crescimento do Endotélio Vascular/metabolismo , Linfangiogênese/genética , Fator B de Crescimento do Endotélio Vascular/metabolismo , Adesivo Tecidual de Fibrina/farmacologia , Adesivo Tecidual de Fibrina/metabolismo , Fator C de Crescimento do Endotélio Vascular/metabolismo , Células Endoteliais da Veia Umbilical Humana/metabolismo
10.
Cir Cir ; 91(2): 212-217, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37084310

RESUMO

BACKGROUND: The effect of tissue adhesives on coronary grafts in cardiac surgery is a controversial issue. OBJECTIVE: The aim of this study is to investigate the effect of fibrin glue (FG) applied around the saphenous vein grafts (SVG) in preventing cellular damage resulting from intraluminal pressure increase. METHODS: Twenty volunteer patients were included in this ex vivo study. The SVGs remained after coronary artery bypass grafting were connected to the arterial line of the cardiopulmonary bypass circuit. The grafts were divided into two segments and one segment received perivascular FG applied whereas the other part was used plain. SVGs were kept in circulation at 120 mmHg pressure 250 mL/min flow rate for 60 min. The tissues were sent for histopathological examination to determine the endothelial damage. RESULTS: Endothelial damage was more pronounced in the control group when compared with the FG group. In the FG group, no damage was seen in 13 samples and no Type 3 endothelial damage was observe whereas Type 1 injury was detected in seven specimens, Type 2 injury was observed in seven specimens, and Type 3 injury was detected in two specimens in the control group. CONCLUSION: Perivascular application of FG on the SVG showed a protective effect against endothelial damage resulting from increased intraluminal pressure.


ANTECEDENTES: El efecto de los adhesivos tisulares sobre los injertos coronarios en cirugía cardíaca es un tema controvertido. OBJETIVO: Investigar el efecto del pegamento de fibrina aplicado alrededor de los injertos de vena safena para prevenir el daño celular resultante del aumento de la presión intraluminal. MÉTODO: En este estudio ex vivo fueron incluidos 20 pacientes voluntarios. Los injertos de vena safena que quedaron después del injerto de derivación de la arteria coronaria se conectaron a la línea arterial del circuito de derivación cardiopulmonar. Los injertos se dividieron en dos segmentos y a uno de ellos se le aplicó pegamento de fibrina perivascular, mientras que la otra parte se usó sola. Los injertos de vena safena se mantuvieron en circulación a una presión de 120 mmHg y una velocidad de flujo de 250 ml/min durante 60 minutos. Los tejidos se enviaron para examen histopatológico para determinar el daño endotelial. RESULTADOS: El daño endotelial fue más pronunciado en el grupo de control que en el grupo de pegamento de fibrina. Se observó lesión de tipo 2 en siete muestras del grupo de pegamento de fibrina y lesión de tipo 3 en dos muestras del grupo de control. CONCLUSIONES: La aplicación perivascular de pegamento de fibrina en los injertos de vena safena mostró un efecto protector contra el daño endotelial resultante del aumento de la presión intraluminal.


Assuntos
Adesivo Tecidual de Fibrina , Veia Safena , Humanos , Adesivo Tecidual de Fibrina/farmacologia , Adesivo Tecidual de Fibrina/uso terapêutico , Veia Safena/transplante , Ponte de Artéria Coronária/métodos , Modelos Teóricos
11.
Muscle Nerve ; 67(6): 522-536, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36905197

RESUMO

INTRODUCTION/AIMS: Peripheral nerve injuries result in impaired neuromuscular interactions, leading to morphological and functional alterations. Adjuvant suture repair methods have been used to improve nerve regeneration and modulate the immune response. Heterologous fibrin biopolymer (HFB), a scaffold with adhesive properties, plays a critical role in tissue repair. The aim of this study is to evaluate neuroregeneration and immune response focusing on neuromuscular recovery, using suture-associated HFB for sciatic nerve repair. METHODS: Forty adult male Wistar rats were distributed into four groups (n = 10): C (control), only sciatic nerve location; D (denervated), neurotmesis and 6-mm gap removal and fixation stumps in subcutaneous tissue; S (suture), neurotmesis followed by suture; and SB (suture + HFB), neurotmesis followed by suture and HFB. Analysis of M2 macrophages (CD206+ ), as well as the morphology and morphometry of nerves, soleus muscle, and neuromuscular junctions (NMJs), were performed at 7 and 30 days after surgery. RESULTS: The SB group had the highest M2 macrophage area in both periods. After 7 days, SB was the only group similar to the C group regarding the number of axons; furthermore, after 30 days, the SB group was closer to the C group concerning blood vessel and central myonuclear numbers, NMJ angle, and connective tissue volume. After 7 days, increases in nerve area, as well as the number and area of blood vessels, were also observed in SB. DISCUSSION: HFB potentiates the immune response, increases axonal regeneration, induces angiogenesis, prevents severe muscle degeneration, and assists in NMJ recovery. In conclusion, suture-associated HFB has major implications for improved peripheral nerve repair.


Assuntos
Adesivo Tecidual de Fibrina , Fibrina , Ratos , Animais , Masculino , Adesivo Tecidual de Fibrina/farmacologia , Ratos Wistar , Nervo Isquiático/lesões , Biopolímeros , Regeneração Nervosa , Suturas
12.
Commun Biol ; 6(1): 192, 2023 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-36801914

RESUMO

Erythrocytes are deformable cells that undergo progressive biophysical and biochemical changes affecting the normal blood flow. Fibrinogen, one of the most abundant plasma proteins, is a primary determinant for changes in haemorheological properties, and a major independent risk factor for cardiovascular diseases. In this study, the adhesion between human erythrocytes is measured by atomic force microscopy (AFM) and its effect observed by micropipette aspiration technique, in the absence and presence of fibrinogen. These experimental data are then used in the development of a mathematical model to examine the biomedical relevant interaction between two erythrocytes. Our designed mathematical model is able to explore the erythrocyte-erythrocyte adhesion forces and changes in erythrocyte morphology. AFM erythrocyte-erythrocyte adhesion data show that the work and detachment force necessary to overcome the adhesion between two erythrocytes increase in the presence of fibrinogen. The changes in erythrocyte morphology, the strong cell-cell adhesion and the slow separation of the two cells are successfully followed in the mathematical simulation. Erythrocyte-erythrocyte adhesion forces and energies are quantified and matched with experimental data. The changes observed on erythrocyte-erythrocyte interactions may give important insights about the pathophysiological relevance of fibrinogen and erythrocyte aggregation in hindering microcirculatory blood flow.


Assuntos
Eritrócitos , Adesivo Tecidual de Fibrina , Humanos , Adesivo Tecidual de Fibrina/metabolismo , Adesivo Tecidual de Fibrina/farmacologia , Microcirculação , Eritrócitos/metabolismo , Fibrinogênio/metabolismo , Modelos Teóricos
13.
Nat Commun ; 14(1): 1029, 2023 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-36823141

RESUMO

Fibrin is the provisional matrix formed after injury, setting the trajectory for the subsequent stages of wound healing. It is commonly used as a wound sealant and a natural hydrogel for three-dimensional (3D) biophysical studies. However, the traditional thrombin-driven fibrin systems are poorly controlled. Therefore, the precise roles of fibrin's biophysical properties on fibroblast functions, which underlie healing outcomes, are unknown. Here, we establish a snake venom-controlled fibrin system with precisely and independently tuned architectural and mechanical properties. Employing this defined system, we show that fibrin architecture influences fibroblast survival, spreading phenotype, and differentiation. A fine fibrin architecture is a key prerequisite for fibroblast differentiation, while a coarse architecture induces cell loss and disengages fibroblast's sensitivity towards TGF-ß1. Our results demonstrate that snake venom-controlled fibrin can precisely control fibroblast differentiation. Applying these biophysical principles to fibrin sealants has translational significance in regenerative medicine and tissue engineering.


Assuntos
Adesivo Tecidual de Fibrina , Fibrina , Adesivo Tecidual de Fibrina/farmacologia , Diferenciação Celular , Fibroblastos , Venenos de Serpentes
14.
Surg Infect (Larchmt) ; 24(1): 82-90, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36706256

RESUMO

Background: Fibrin sealants are used as antimicrobial-releasing carriers for preventing surgical site infections; however, it is important to determine the release kinetics and antimicrobial effects of drugs added to fibrin sealants and the effects of drugs on clot/clotting properties. Materials and Methods: The antimicrobial and antibiofilm activity of cefazolin, colistin, gentamicin, oxacillin, tobramycin, and silver nitrate released from fibrin sealant were characterized using in vitro and ex vivo assays against bacteria commonly found on the skin. The effects of antimicrobial agents on the physical structure of the fibrin sealant were assessed with scanning electron microscopy (SEM) and on the clotting rate and strength of fibrin clots using run-off tests and rheology. Results: Generally, antibiotic agents were released gradually from fibrin sealant and were stable after release, with antimicrobial effects evident up to three days. Cefazolin, gentamicin, and oxacillin prevented biofilm formation of Staphylococcus aureus in porcine skin explants; gentamicin and colistin prevented biofilm formation of Pseudomonas aeruginosa. Gentamicin, cefazolin, colistin, and tobramycin did not affect the structural integrity or viscoelastic properties of fibrin sealant; changes were observed with oxacillin (SEM) and particularly silver nitrate (SEM and rheology). No antimicrobial agents caused deterioration of clotting time (run-off tests). Conclusions: From the antimicrobial agents tested, gentamicin and cefazolin showed prolonged release from fibrin sealant, sustained antimicrobial activity, and biofilm prevention properties against Staphylococcus aureus; similar results were observed for gentamicin and colistin against Pseudomonas aeruginosa. For each of these findings, the physical structure of the fibrin sealant, clotting rate, and strength of fibrin clots were unaffected.


Assuntos
Adesivo Tecidual de Fibrina , Infecções Estafilocócicas , Animais , Suínos , Adesivo Tecidual de Fibrina/farmacologia , Adesivo Tecidual de Fibrina/química , Cefazolina , Colistina , Nitrato de Prata , Antibacterianos/uso terapêutico , Gentamicinas/farmacologia , Oxacilina , Tobramicina , Infecções Estafilocócicas/tratamento farmacológico
15.
J Biomed Mater Res A ; 111(4): 488-501, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36355631

RESUMO

Fibrin sealants are well-established components of the surgical toolbox, especially in procedures that harbor a high risk of perioperative bleeding. Their widespread use as hemostats, sealants or tissue-adhesives in various surgical settings has shown that the choice of the appropriate sealant system affects the clinical outcome. While many studies have compared the hemostatic efficiency of fibrin sealants to that of other natural or synthetic sealants, there is still limited data on how subtle differences in fibrin sealant formulations relate to their biological performance. Here, we performed an in-depth physicochemical and biological characterization of the two most commonly used fibrin sealants in the US and Europe: TISSEEL™ ("FS") and VISTASEAL™/VERASEAL™ ("FS+Osm"). Our chemical analyses demonstrated differences between the two sealants, with lower fibrinogen concentrations and supraphysiological osmolality in the FS+Osm formulation. Rheological testing revealed FS clots have greater clot stiffness, which strongly correlated with network density. Ultrastructural analysis by scanning electron microscopy revealed differences between FS and FS+Osm fibrin networks, the latter characterized by a largely amorphous hydrogel structure in contrast to the physiological fibrillar network of FS. Cytocompatibility experiments with human fibroblasts seeded on FS and FS+Osm fibrin networks, or cultured in presence of sealant extracts, revealed that FS+Osm induced apoptosis, which was not observed with FS. Although differential sealant osmolality and amounts of fibrinogen, as well as the presence of Factor XIII or additives such as antifibrinolytics, may explain the mechanical and structural differences observed between the two fibrin sealants, none of these substances are known to cause apoptosis at the respective concentrations in the sealant formulation. We thus conclude that hyper osmolality in the FS+Osm formulation is the primary trigger of apoptosis-a mechanism that should be evaluated in more detail, as it may affect the cellular wound healing response in situ.


Assuntos
Hemostáticos , Adesivos Teciduais , Humanos , Adesivo Tecidual de Fibrina/análise , Adesivo Tecidual de Fibrina/química , Adesivo Tecidual de Fibrina/farmacologia , Hemostáticos/farmacologia , Cicatrização , Adesivos Teciduais/química , Fibrinogênio/farmacologia
16.
Neurol India ; 71(6): 1177-1182, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38174454

RESUMO

Objective: Histopathological examination of the effects of Tisseel, Cova, Glubran and Coseal, which are used for sealing purposes in spinal surgery practice, on epidural fibrosis is aimed. Methods: Forty Sprague Dawley rats were randomly divided into five groups in our study as Group 1 (n=8) control group (Laminectomy); Group 2 (n=8) Cova group (Laminectomy + Cova); Group 3 (n=8) Tissel group (Laminectomy + Tisseel); Group 4 (n=8) Coseal group (Laminectomy + Coseal); and Group 5 Glubrane group (Laminectomy + Glubrane). Control group was only applied laminectomy. After laminectomy to other groups, Cova was applied to the 2nd group, Tissel to the 3rd group, Coseal to the 4th group and Glubran to the 5th group in surgical fields. After the rats were monitored in separate cages for 6 weeks after the operation, the relevant spinal level was extracted and the samples were examined histopathologically and the results were evaluated statistically. Results: It was found that there was a statistically significant difference in Tisseel and Glubran groups in terms of fibrosis grading compared to the control group, and this had a positive effect on fibrosis. Compared to the control group, there was no statistically significant difference on fibrosis in Cova and Coseal groups. Conclusion: As dura adhesive agents used in spinal surgery practice did not increase spinal epidural fibrosis statistically significantly, we concluded that these products can be used safely during spinal surgery if necessary.


Assuntos
Adesivo Tecidual de Fibrina , Laminectomia , Ratos , Animais , Ratos Sprague-Dawley , Adesivo Tecidual de Fibrina/farmacologia , Fibrose , Laminectomia/métodos , Modelos Animais de Doenças , Espaço Epidural/cirurgia
17.
Sci Rep ; 12(1): 20660, 2022 11 30.
Artigo em Inglês | MEDLINE | ID: mdl-36450814

RESUMO

During Autologous Matrix-Induced Chondrogenesis (AMIC), the membrane is often glued into the chondral defect. However, whether fibrin glue influences cells proliferation and migration remain unclear. This study evaluated the impact of fibrin glue addition to biologic membranes loaded with bone marrow-derived mesenchymal stem cells (B-MSCs). A porcine derived collagen membrane (Cartimaix, Matricel GmbH, Germany) was used. B-MSCs were harvested from three different unrelated donors. The membranes were embedded in mounting medium with DAPI (ABCAM, Cambridge, UK) and analysed at 1-, 2-, 3-, 4-, 6-, and at 8-week follow-up. The DAPI ties the DNA of the cell nucleus, emitting blue fluorescence. DAPI/nuclei signals were analysed with fluorescence microscopy at 100-fold magnification. The group without fibrin glue demonstrated greater migration of the B-MSCs within the membrane at week 4 (P < 0.001), 6 (P < 0.001), and 8 (P < 0.001). No difference was found at week 1, 2, and 3. The group without fibrin glue demonstrated greater proliferation of B-MSCs within the membrane. These differences were significant at week 1 (P = 0.02), 2 (P = 0.008), 3 (P = 0.0009), 4 (P < 0.0001), 6 (P < 0.0001), 8 (P < 0.0001). Concluding, in the present setting, the use of fibrin in a collagenic biomembrane impairs B-MSCs proliferation and migration in vitro.


Assuntos
Adesivo Tecidual de Fibrina , Células-Tronco Mesenquimais , Suínos , Animais , Adesivo Tecidual de Fibrina/farmacologia , Medula Óssea , Colágeno , Proliferação de Células
18.
Am J Sports Med ; 50(9): 2515-2525, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35736385

RESUMO

BACKGROUND: Point-of-care treatment options for medium to large symptomatic articular cartilage defects are limited. Minced cartilage implantation is an encouraging single-stage option, providing fresh viable autologous tissue with minimal morbidity and cost. PURPOSE: To determine the histological properties of mechanically minced versus minimally manipulated articular cartilage. STUDY DESIGN: Controlled laboratory study. METHODS: Remnant articular cartilage was collected from fresh femoral condylar allografts. Cartilage samples were divided into 4 groups: cartilage explants with or without fibrin glue and mechanically minced cartilage with or without fibrin glue. Samples were cultured for 42 days. Chondrocyte viability was assessed using live/dead assay. Cellular migration and outgrowth were monitored using bright-field microscopy. Extracellular matrix deposition was assessed via histological staining. Proteoglycan content and synthesis were assessed using dimethylmethylene blue assay and radiolabeled 35S-sulfate, respectively. Type II collagen (COL2A1) gene expression was analyzed via polymerase chain reaction. RESULTS: The mean viability of minced cartilage particles (34% ± 14%) was not significantly reduced compared with baseline (46% ± 13%) on day 0 (P = .90). After culture, no significant difference in the percentage of live cells was appreciated between mechanically minced (58% ± 23%) and explant (73% ± 14%) cartilage in the presence of fibrin glue (P = .52). The addition of fibrin glue did not significantly affect the viability of cartilage samples. The qualitative assessment revealed comparable cellular migration and outgrowth between groups. Proteoglycan synthesis was not significantly different between groups. Histological analysis findings were positive for COL2A1 in all groups, and matrix formation was appreciated in all groups. COL2A1 expression in minced cartilage (1.72 ± 1.88) was significantly higher than in explant cartilage (0.15 ± 0.07) in the presence of fibrin glue (P = .01). CONCLUSION: Mechanically minced articular cartilage remained viable after 42 days of culture in vitro and was comparable with cartilage explants with regard to cellular migration, outgrowth, and extracellular matrix synthesis. CLINICAL RELEVANCE: Mechanically minced articular cartilage is an encouraging intervention for the treatment of symptomatic cartilage defects. Further translational work is warranted to determine the viability of minced cartilage implantation as a single-stage therapeutic intervention in vivo.


Assuntos
Cartilagem Articular , Cartilagem Articular/metabolismo , Condrócitos/transplante , Adesivo Tecidual de Fibrina/farmacologia , Humanos , Articulação do Joelho/cirurgia , Proteoglicanas/metabolismo
19.
J Orthop Surg Res ; 17(1): 311, 2022 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-35690862

RESUMO

BACKGROUND: Some authors secured the membrane during matrix-induced autologous chondrocyte implantation (mACI) with fibrin glue or did not use a formal fixation. The real impact of fibrin glue addition on chondrocytes migration and proliferation has not yet been clarified. This study evaluated the impact of fibrin glue on a chondrocyte loaded collagenic membrane. METHODS: A resorbable collagen I/III porcine derived membrane commonly employed in AMIC was used for all experiments. Chondrocytes from three difference donors were used. At 1-, 2-, 3-, 4-, 6-, and at 8-week the membranes were embedded in Mounting Medium with Dapi (ABCAM, Cambridge, UK). The Dapi contained in the mounting medium ties the DNA of the cell nucleus and emits a blue fluorescence. In this way, the spreading of the cells in the membrane can be easily monitored. The outcomes of interest were to evaluate (1) cell migration and (2) cell proliferation within the porous membrane layer. DAPI/nuclei signals were analysed with fluorescence microscope under a magnification of 100-fold. RESULTS: The no-fibrin group demonstrated greater migration of the cells within the membrane. Although migration resulted higher in the no-fibrin group at every follow-up, this difference was significant only at week 1 (P < 0.001), 2 (P = 0.004), and 3 (P = 0.03). No difference was found at week 3, 6, and 8. The no-fibrin group demonstrated greater proliferation of the chondrocytes within the membrane. These differences were significant at week 4 (P < 0.0001), 6 (P < 0.0001), 8 (P < 0.0001). CONCLUSION: The use of fibrin glue over a resorbable membrane leads to lower in vitro proliferation and migration of chondrocytes.


Assuntos
Cartilagem Articular , Condrócitos , Animais , Cartilagem Articular/cirurgia , Proliferação de Células , Células Cultivadas , Condrócitos/metabolismo , Colágeno/metabolismo , Colágeno/farmacologia , Fibrina , Adesivo Tecidual de Fibrina/metabolismo , Adesivo Tecidual de Fibrina/farmacologia , Suínos
20.
J Shoulder Elbow Surg ; 31(11): e519-e533, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35690347

RESUMO

BACKGROUND: It has been shown that subacromial bursa (SAB) harbors connective tissue progenitor cells. The purpose of this study was to evaluate the effects of implantation of SAB-derived cells (SBCs) suspended in a fibrin sealant bead and implantation of SAB tissue at rotator cuff repair site on biomechanical properties of the repair in a mouse (C57Bl/6) model of supraspinatus tendon (ST) detachment and repair. METHODS: Part 1: Murine SAB tissue was harvested and cultured. Viability of SBCs suspended in 10 µL of fibrin sealant beads was confirmed in vitro and in vivo. Eighty mice underwent right ST detachment and repair augmented with either fibrin sealant bead (control group) or fibrin sealant bead with 100,000 SBCs (study group) applied at the repair site. Part 2: 120 mice underwent right ST detachment and repair and were randomized equally into 4 groups: (1) a tissue group, which received a piece of freshly harvested SAB tissue; (2) a cell group, which received SBCs suspended in fibrin sealant bead; (3) a fibrin sealant group, which received plain fibrin sealant bead without cells; and (4) a control group, which received nothing at the ST repair site. An equal number of mice in each group were killed at 2 and 4 weeks. Specimens underwent biomechanical testing to evaluate failure force (part 1 and 2) and histologic analysis of the repair site (part 1 only). RESULTS: Part 1: The mean failure force in the study group was significantly higher than controls at 2 and 4 weeks (3.25 ± 1.03 N vs. 2.43 ± 0.56 N, P = .01, and 4.08 ± 0.99 N vs. 3.02 ± 0.8 N, P = .004, respectively). Mean cell density of the ST at the repair site was significantly lower in the study group at 2 weeks than in controls (18,292.13 ± 1706.41 vs. 29,501.90 ± 3627.49, P = .001). Study group specimens had lower proteoglycan contents than controls, but this difference was not statistically significant. Part 2: There was no difference in failure force between cell and tissue groups at the 2- and 4-week time points (P = .994 and P = .603, respectively). There was no difference in failure force between fibrin sealant bead and control groups at the 2- and 4-week time points (P = .978 and P = .752, respectively). CONCLUSION: This study shows that the application of SBCs and SAB tissue at the rotator cuff repair site increases the strength of repair in a murine model of rotator cuff detachment and repair.


Assuntos
Lesões do Manguito Rotador , Manguito Rotador , Camundongos , Animais , Manguito Rotador/cirurgia , Lesões do Manguito Rotador/cirurgia , Adesivo Tecidual de Fibrina/farmacologia , Adesivo Tecidual de Fibrina/uso terapêutico , Modelos Animais de Doenças , Camundongos Endogâmicos C57BL , Proteoglicanas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...